This research was performed within the framework of the Eindhoven MedTech Innovation Center (e/MTIC). e/MTIC had no role in the study design, collection, analysis and interpretation of data, nor in writing the manuscript or the decision to submit the manuscript for publication. This research was funded by a Horizon 2020 grant and supported by Nemo Healthcare BV (grant number 719500). Nemo Healthcare BV is a spin-off company from the Eindhoven University of Technology (TUe). The Maxima Medical Center has a research collaboration with Nemo Healthcare.

Análisis de autorías institucional

Cuerva, Marcos JavierAutor o Coautor

Compartir

Publicaciones
>
Artículo

Intrapartum non-invasive electrophysiological monitoring: A prospective observational study

Publicado en:ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA. 99 (10): 1387-1395 - 2020-10-01 99(10), DOI: 10.1111/aogs.13873

Autores: Lempersz, Carlijn; Noben, Lore; van Osta, Gonnie; Wassen, Martine L. H.; Meershoek, Bert P. J.; Bakker, Petra; Jacquemyn, Yves; Cuerva, Marcos Javier; Vullings, Rik; Westerhuis, Michelle E. M. H.; Oei, S. Guid;

Afiliaciones

BV Data Anal & Reporting, Hilversum, Netherlands - Autor o Coautor
Eindhoven MedTech Innovat Ctr E MTIC, Eindhoven, Netherlands - Autor o Coautor
Eindhoven Univ Technol, Dept Elect Engn, Eindhoven, Netherlands - Autor o Coautor
Maxima Med Ctr, Dept Obstet & Gynecol, Veldhoven, Netherlands - Autor o Coautor
Univ Amsterdam, Med Ctr, Dept Obstet & Gynecol, Amsterdam, Netherlands - Autor o Coautor
Univ Hosp Antwerp, Dept Obstet & Gynecol, Antwerp, Belgium - Autor o Coautor
Univ Hosp La Paz, Dept Obstet & Gynecol, Madrid, Spain - Autor o Coautor
Van Weel Bethesda Hosp, Dept Obstet & Gynecol, Dirksland, Netherlands - Autor o Coautor
Zuyderland Med Ctr, Dept Obstet & Gynecol, Heerlen, Netherlands - Autor o Coautor
Ver más

Resumen

Introduction Doppler ultrasound cardiotocography is a non-invasive alternative that, despite its poor specificity, is often first choice for intrapartum monitoring. Doppler ultrasound suffers from signal loss due to fetal movements and is negatively correlated with maternal body mass index (BMI). Reported accuracy of fetal heart rate monitoring by Doppler ultrasound varies between 10.6 and 14.3 bpm and reliability between 62.4% and 73%. The fetal scalp electrode (FSE) is considered the reference standard for fetal monitoring but can only be applied after membranes have ruptured with sufficient cervical dilatation and is sometimes contra-indicated. A non-invasive alternative that overcomes the shortcomings of Doppler ultrasound, providing reliable information on fetal heart rate, could be the answer. Non-invasive fetal electrocardiography (NI-fECG) uses a wireless electrode patch on the maternal abdomen to obtain both fetal and maternal heart rate signals as well as an electrohysterogram. We aimed to validate a wireless NI-fECG device for intrapartum monitoring in term singleton pregnancies, by comparison with the FSE.Material and methods We performed a multicenter cross-sectional observational study at labor wards of 6 hospitals located in the Netherlands, Belgium, and Spain. Laboring women with a healthy singleton fetus in cephalic presentation and gestational age between 36 and 42 weeks were included. Participants received an abdominal electrode patch and FSE after written informed consent. Accuracy, reliability, and success rate of fetal heart rate readings were determined, using FSE as reference standard. Analysis was performed for the total population and measurement period as well as separated by labor stage and BMI class (<= 30 and >30 kg/m(2)).Results We included a total of 125 women. Simultaneous registrations with NI-fECG and FSE were available in 103 women. Overall accuracy is -1.46 bpm and overall reliability 86.84%. Overall success rate of the NI-fECG is around 90% for the total population as well as for both BMI subgroups. Success rate dropped to 63% during second stage of labor, similar results are found when looking at the separate BMI groups.Conclusions Performance measures of the NI-fECG device are good in the overall group and the separate BMI groups. Compared with Doppler ultrasound performance measures from the literature, NI-fECG is a more accurate alternative. Especially, when women have a higher BMI, NI-fECG performs well, resembling FSE performance measures.

Palabras clave

fetal monitoringfetusheart rate monitoringlaborAccuracyAgreementBody-mass indexCardiotocographyComplicationsElectrohysterographyFetal electrocardiogramFetal monitoringFetusHeart rate monitoringLaborNon-invasive fetal electrocardiographyOutcomesReliabilityTrial

Indicios de calidad

Impacto bibliométrico. Análisis de la aportación y canal de difusión

El trabajo ha sido publicado en la revista ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA debido a la progresión y el buen impacto que ha alcanzado en los últimos años, según la agencia WoS (JCR), se ha convertido en una referencia en su campo. En el año de publicación del trabajo, 2020, se encontraba en la posición 19/83, consiguiendo con ello situarse como revista Q1 (Primer Cuartil), en la categoría Obstetrics & Gynecology.

Desde una perspectiva relativa, y atendiendo al indicador del impacto normalizado calculado a partir de las Citas Mundiales proporcionadas por WoS (ESI, Clarivate), arroja un valor para la normalización de citas relativas a la tasa de citación esperada de: 1.02. Esto indica que, de manera comparada con trabajos en la misma disciplina y en el mismo año de publicación, lo ubica como trabajo citado por encima de la media. (fuente consultada: ESI 14 Nov 2024)

Esta información viene reforzada por otros indicadores del mismo tipo, que aunque dinámicos en el tiempo y dependientes del conjunto de citaciones medias mundiales en el momento de su cálculo, coinciden en posicionar en algún momento al trabajo, entre el 50% más citados dentro de su temática:

  • Media Ponderada del Impacto Normalizado de la agencia Scopus: 1.45 (fuente consultada: FECYT Feb 2024)
  • Field Citation Ratio (FCR) de la fuente Dimensions: 6.73 (fuente consultada: Dimensions Jun 2025)

De manera concreta y atendiendo a las diferentes agencias de indexación, el trabajo ha acumulado, hasta la fecha 2025-06-19, el siguiente número de citas:

  • WoS: 9
  • Scopus: 20
  • OpenCitations: 15

Impacto y visibilidad social

Desde la dimensión de Influencia o adopción social, y tomando como base las métricas asociadas a las menciones e interacciones proporcionadas por agencias especializadas en el cálculo de las denominadas “Métricas Alternativas o Sociales”, podemos destacar a fecha 2025-06-19:

  • La utilización de esta aportación en marcadores, bifurcaciones de código, añadidos a listas de favoritos para una lectura recurrente, así como visualizaciones generales, indica que alguien está usando la publicación como base de su trabajo actual. Esto puede ser un indicador destacado de futuras citas más formales y académicas. Tal afirmación es avalada por el resultado del indicador “Capture” que arroja un total de: 53 (PlumX).

Análisis de liderazgo de los autores institucionales

Este trabajo se ha realizado con colaboración internacional, concretamente con investigadores de: Belgium; Netherlands.