A randomised trial of paclitaxel-eluting balloon after bare metal stent implantation vs. bare metal stent in ST-elevation myocardial infarction (the PEBSI study)

Publicado en:EuroIntervention. 12 (13): 1587-1594 - 2017-01-01 12(13), DOI: 10.4244/EIJ-D-16-00128

Autores: García-Touchard A; Goicolea J; Sabaté M; Alfonso F; Ruiz-Salmerón R; Bethencourt A; Gonzalo N; Miranda F; Del Blanco B; Jiménez-Mazuecos J; Melgares R; Martínez-Romero P; Hernandez-García J; Lezaún R; Bullones J; Fernández-Portales J; Rumoroso J; Ortas R; Valdés M; Trillo R; Brugaletta S; Otzuki S; Hernández-Pérez F; Alonso-Pulpón L

Afiliaciones

Complejo Hosp Univ Albacete, Albacete, Spain - Autor o Coautor
Hosp Arnau Vilanova, Lleida, Spain      University Hospital Arnau de Vilanova - Autor o Coautor
Hosp Carlos Haya, Malaga, Spain      Hospital Carlos Haya       - Autor o Coautor
Hosp Clin Barcelona, Barcelona, Spain      Hospital Clinic de Barcelona    University of Barcelona - Autor o Coautor
Hosp Clin San Carlos, Madrid, Spain      Hospital Clinico San Carlos - Autor o Coautor
Hosp Clin Univ Santiago, La Corttna, Spain - Autor o Coautor
Hosp del Mar, Barcelona, Spain      Institut Hospital del Mar d'Investigacions Mediques (IMIM)    Hospital del Mar - Autor o Coautor
Hosp Galdakao Usansolo, Galdakao, Spain      Galdakao Hospital - Autor o Coautor
Hosp Princesa, Madrid, Spain      Hospital de La Princesa - Autor o Coautor
Hosp Puerto Real, Puerto Real, Spain      Universidad de Cadiz    Hospital Universitario Puerto Real - Autor o Coautor
Hosp San Pedro de Alcantara, Caceres, Spain - Autor o Coautor
Hosp Univ Navarra, Navarra, Spain      University of Navarra - Autor o Coautor
Hosp Univ Puerta de Hierro Majadahonda, Dept Intervent Cardiol, Manuel Falla,1, Majadahonda 28220, Spain.      Hospital Puerta de Hierro-Majadahonda - Autor o Coautor
Hosp Univ Puerta Hierro, Majadahonda, Spain      Hospital Puerta de Hierro-Majadahonda - Autor o Coautor
Hosp Univ Son Espases, Balearic Islands, Spain      Hospital Universitario Son Espases - Autor o Coautor
Hosp Univ Vall Hebron, Barcelona, Spain      Hospital Universitari Vall d'Hebron       - Autor o Coautor
Hosp Univ Virgen De La Victoria, Malaga, Spain      Universidad de Malaga    Hospital Virgen de la Victoria - Autor o Coautor
Hosp Univ Virgen de las Nieves, Granada, Spain      Hospital Universitario Virgen de las Nieves - Autor o Coautor
Hosp Virgen Arrixaca, Murcia, Spain      Hospital Clinico Universitario Virgen de la Arrixaca       - Autor o Coautor
Hosp Virgen Macarena, Seville, Spain      Hospital Universitario Virgen Macarena - Autor o Coautor
Ver más

Resumen

Our aim was to assess the safety and efficacy of paclitaxel-eluting balloon (PTX-B) treatment after bare metal stent (BMS) implantation in patients undergoing primary angioplasty.After BMS implantation, patients were randomised (1:1) to treatment with a PTX-B or no PTX-B treatment (BMS group). The primary endpoint was in-stent late luminal loss (LLL) at nine-month follow-up. OCT was carried out on the first 20% of consecutive patients included in the study. Two hundred and twenty-three patients were randomised (BMS: 112, PTX-B: 111). At nine months, median LLL was 0.80 mm (interquartile range [IQR] 0.36-1.26) in the BMS group vs. 0.31 mm (IQR 0.00-0.58) in the PTX-B group, p<0.0001. Binary restenosis was significantly lower in the PTX-B group: 29.8% vs. 2.2%, p<0.0001, 95% confidence interval (CI): 3.2-54.2. Nine-month OCT showed good strut coverage in both groups but greater in the BMS group (100±0.0% vs. 99.52±1.11%, p=0.03) with very low rates of malapposed struts per lesion. One-year MACE was significantly lower in the PTX-B group (12.5% vs. 3.6%, p=0.016).PTX-B after successful BMS implantation resulted in less LLL and better clinical outcomes as compared with a BMS-only strategy. This was associated with good stent strut coverage and very low rates of malapposed struts.

Palabras clave

Myocardial infarctionPaclitaxel-eluting balloonPrimary angioplastySt-segment elevationStent

Indicios de calidad

Impacto bibliométrico. Análisis de la aportación y canal de difusión

El trabajo ha sido publicado en la revista EuroIntervention debido a la progresión y el buen impacto que ha alcanzado en los últimos años, según la agencia Scopus (SJR), se ha convertido en una referencia en su campo. En el año de publicación del trabajo, 2017, se encontraba en la posición , consiguiendo con ello situarse como revista Q1 (Primer Cuartil), en la categoría Medicine (Miscellaneous). Destacable, igualmente, el hecho de que la Revista está posicionada por encima del Percentil 90.

Desde una perspectiva relativa, y atendiendo al indicador del impacto normalizado calculado a partir de las Citas Mundiales de Scopus Elsevier, arroja un valor para la media Ponderada del Impacto Normalizado de la agencia Scopus: 3.26, lo que indica que, de manera comparada con trabajos en la misma disciplina y en el mismo año de publicación, lo ubica como trabajo citado por encima de la media. (fuente consultada: ESI 14 Nov 2024)

Esta información viene reforzada por otros indicadores del mismo tipo, que aunque dinámicos en el tiempo y dependientes del conjunto de citaciones medias mundiales en el momento de su cálculo, coinciden en posicionar en algún momento al trabajo, entre el 50% más citados dentro de su temática:

  • Field Citation Ratio (FCR) de la fuente Dimensions: 3.88 (fuente consultada: Dimensions Jun 2025)

De manera concreta y atendiendo a las diferentes agencias de indexación, el trabajo ha acumulado, hasta la fecha 2025-06-24, el siguiente número de citas:

  • WoS: 14
  • Scopus: 14
  • Europe PMC: 5
  • OpenCitations: 13

Impacto y visibilidad social

Desde la dimensión de Influencia o adopción social, y tomando como base las métricas asociadas a las menciones e interacciones proporcionadas por agencias especializadas en el cálculo de las denominadas “Métricas Alternativas o Sociales”, podemos destacar a fecha 2025-06-24:

  • La utilización de esta aportación en marcadores, bifurcaciones de código, añadidos a listas de favoritos para una lectura recurrente, así como visualizaciones generales, indica que alguien está usando la publicación como base de su trabajo actual. Esto puede ser un indicador destacado de futuras citas más formales y académicas. Tal afirmación es avalada por el resultado del indicador “Capture” que arroja un total de: 70 (PlumX).

Análisis de liderazgo de los autores institucionales

Este trabajo se ha realizado con colaboración internacional, concretamente con investigadores de: Granada.

Existe un liderazgo significativo ya que algunos de los autores pertenecientes a la institución aparecen como primer o último firmante, se puede apreciar en el detalle: Último Autor (ALONSO-PULPON RIVERA, LUIS ANTONIO).