The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: The study was funded by the Spanish Ministry of Economy and Competitiveness through Project (PI18/01365) and by the UPV/IIS LA Fe through the (Endoworm 3.0) Project. CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program, CIBER Actions and financed by the Instituto de Salud Carlos III with the assistance of the European Regional Development Fund.

Análisis de autorías institucional

Sanchez, CarlosAutor o Coautor

Compartir

Publicaciones
>
Artículo

Analysis of the 'Endoworm' prototype's ability to grip the bowel in in vitro and ex vivo models

Publicado en:PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE. 234 (5): 0954411920901414-477 - 2020-01-25 234(5), DOI: 10.1177/0954411920901414

Autores: Tobella, Javier; Pons-Beltran, Vicente; Santonja, Alberto; Sanchez, Carlos; Campillo-Fernandez, Alberto J; Vidaurre, Ana

Afiliaciones

Biomed Res Networking Ctr Bioengn Biomat & Nanome, Madrid, Spain - Autor o Coautor
IIS Hosp La Fe, Gastrointestinal Endoscopy Res Grp, Valencia, Spain - Autor o Coautor
La Fe Polytech Univ Hosp, Digest Dis Dept, Digest Endoscopy Unit, Valencia, Spain - Autor o Coautor
Univ Politecn Valencia, Ctr Biomat & Tissue Engn CBIT, Camino Vera S-N, E-46022 Valencia, Spain - Autor o Coautor
Univ Politecn Valencia, Dept Elect Engn, Valencia, Spain - Autor o Coautor
Univ Politecn Valencia, ETSID, Valencia, Spain - Autor o Coautor
Ver más

Resumen

Access to the small bowel by means of an enteroscope is difficult, even using current devices such as single-balloon or double-balloon enteroscopes. Exploration time and patient discomfort are the main drawbacks. The prototype 'Endoworm' analysed in this paper is based on a pneumatic translation system that, gripping the bowel, enables the endoscope to move forward while the bowel slides back over its most proximal part. The grip capacity is related to the pressure inside the balloon, which depends on the insufflate volume of air. Different materials were used as in vitro and ex vivo models: rigid polymethyl methacrylate, flexible silicone, polyester urethane and ex vivo pig small bowel. On measuring the pressure-volume relationship, we found that it depended on the elastic properties of the lumen and that the frictional force depended on the air pressure inside the balloons and the lumen's elastic properties. In the presence of a lubricant, the grip on the simulated intestinal lumens was drastically reduced, as was the influence of the lumen's properties. This paper focuses on the Endoworm's ability to grip the bowel, which is crucial to achieving effective endoscope forward advance and bowel folding.

Palabras clave

BalloonCapsule robotDesignDiagnostic yieldEndoscopyEnteroscopyFrictional resistanceGrip force measuremenIntestineLocomotionMedical control systemsSmall bowelTissuTotal enteroscopy

Indicios de calidad

Impacto bibliométrico. Análisis de la aportación y canal de difusión

El trabajo ha sido publicado en la revista PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE debido a la progresión y el buen impacto que ha alcanzado en los últimos años, según la agencia Scopus (SJR), se ha convertido en una referencia en su campo. En el año de publicación del trabajo, 2020, se encontraba en la posición , consiguiendo con ello situarse como revista Q2 (Segundo Cuartil), en la categoría Mechanical Engineering. Destacable, igualmente, el hecho de que la Revista está posicionada en el Cuartil Q4 para la agencia WoS (JCR) en la categoría Engineering, Biomedical.

2025-06-20:

  • WoS: 4
  • Scopus: 4
  • OpenCitations: 4

Impacto y visibilidad social

Desde la dimensión de Influencia o adopción social, y tomando como base las métricas asociadas a las menciones e interacciones proporcionadas por agencias especializadas en el cálculo de las denominadas “Métricas Alternativas o Sociales”, podemos destacar a fecha 2025-06-20:

  • El uso, desde el ámbito académico evidenciado por el indicador de la agencia Altmetric referido como agregaciones realizadas por el gestor bibliográfico personal Mendeley, nos da un total de: 17.
  • La utilización de esta aportación en marcadores, bifurcaciones de código, añadidos a listas de favoritos para una lectura recurrente, así como visualizaciones generales, indica que alguien está usando la publicación como base de su trabajo actual. Esto puede ser un indicador destacado de futuras citas más formales y académicas. Tal afirmación es avalada por el resultado del indicador “Capture” que arroja un total de: 17 (PlumX).

Con una intencionalidad más de divulgación y orientada a audiencias más generales podemos observar otras puntuaciones más globales como:

  • El Score total de Altmetric: 0.25.
  • El número de menciones en la red social X (antes Twitter): 1 (Altmetric).