{rfName}
My

Indexed in

License and use

Altmetrics

Analysis of institutional authors

Gomez Leon, M? De Las NievesAuthorMoran, Luz MCorresponding Author

Share

Publications
>
Article

Myxomas and myxoid liposarcomas of the extremities: Our preliminary findings in conventional, perfusion, and diffusion magnetic resonance

Publicated to:Acta Radiol Open. 11 (10): 20584601221131481- - 2022-10-01 11(10), DOI: 10.1177/20584601221131481

Authors: Moran, Luz M; Vega, Jesus; Gomez-Leon, Nieves; Royuela, Ana

Affiliations

Hosp Univ Clin San Carlos, Dept Patol, Madrid, Spain - Author
Hosp Univ La Princesa, Dept Radiol, Madrid, Spain - Author
Hosp Univ Puerta Hierro, Dept Radiol, Madrid 28300, Spain - Author
Hosp Univ Puerta Hierro, Dept Stat, Madrid, Spain - Author

Abstract

Background: The differentiation between myxomas and myxoid liposarcomas (MLPS) often is a serious challenge for the radiologists. Magnetic resonance imaging (MRI) is the most useful imaging technique in characterization of the soft tissue tumors (STT). Purpose: To evaluate in a sample of myxomas and MLPS of the extremities, what morphological findings in conventional MRI allow us to differentiate these two types of myxoid tumors, in addition to analyzing the validity of the apparent diffusion coefficient (ADC) values of diffusion-weighted MRI (DW-MRI). Material and Methods: Magnetic resonance imaging studies in myxomas and MLPS of extremities searched in our PACS between 2015 and 2019. All studies had conventional MRI with T1, T2, and PD SPAIR sequences, while DW-MRI with ADC mapping and perfusion MRI with a TI sequence repeated for 4 minutes after contrast injection were additional sequences only in some explorations. Two radiologists evaluated independently the MRI studies by examining the qualitative parameters. Apparent diffusion coefficient values were calculated using two methods-ADC global and ADC solid, and Receiver Operating Characteristic (ROC) curves were applied for analysis. Results: The features were consistent with MLPS: size greater than 10 cm, heterogeneous signal on T1, and nodular enhancement, while the common findings for myxomas were a homogenously hypointense signal on T1 and diffuse peritumoral enhancement. The solid and global ADC values were higher in myxomas. We observed that the solid ADC value less than 2.06 x 10(-3)mm(2) x s would support the diagnosis of MLPS against myxoma. Conclusion: Overall, MRI with its different modalities improved the diagnostic accuracy when differentiating myxomas from MLPS of extremities.

Keywords

Apparent diffusion coefficienApparent diffusion coefficientBenignDiffusion-weighted mriIntramuscular myxomaMagnetic resonance imagingMasseMatrixMrMyxoid liposarcomaMyxomaSoft tissue tumorsSoft-tissue tumors

Quality index

Bibliometric impact. Analysis of the contribution and dissemination channel

From a relative perspective, and based on the normalized impact indicator calculated from World Citations provided by WoS (ESI, Clarivate), it yields a value for the citation normalization relative to the expected citation rate of: 2.03. This indicates that, compared to works in the same discipline and in the same year of publication, it ranks as a work cited above average. (source consulted: ESI Nov 14, 2024)

This information is reinforced by other indicators of the same type, which, although dynamic over time and dependent on the set of average global citations at the time of their calculation, consistently position the work at some point among the top 50% most cited in its field:

  • Field Citation Ratio (FCR) from Dimensions: 5.12 (source consulted: Dimensions Jul 2025)

Specifically, and according to different indexing agencies, this work has accumulated citations as of 2025-07-01, the following number of citations:

  • WoS: 6
  • Europe PMC: 4

Impact and social visibility

From the perspective of influence or social adoption, and based on metrics associated with mentions and interactions provided by agencies specializing in calculating the so-called "Alternative or Social Metrics," we can highlight as of 2025-07-01:

  • The use of this contribution in bookmarks, code forks, additions to favorite lists for recurrent reading, as well as general views, indicates that someone is using the publication as a basis for their current work. This may be a notable indicator of future more formal and academic citations. This claim is supported by the result of the "Capture" indicator, which yields a total of: 7 (PlumX).

Leadership analysis of institutional authors

There is a significant leadership presence as some of the institution’s authors appear as the first or last signer, detailed as follows: First Author (MORAN BLANCO, LUZ MARIA) .

the author responsible for correspondence tasks has been MORAN BLANCO, LUZ MARIA.